Auxiliary Equipment

Booster Pump

It is centrifugal "stuffing" pump which supplies raw milk to the raw regenerator for the balance tank. It must be used in conjunction with pressure differential controlling device and shall operate only when timing pump is operating, proper pressures are achieved in regenerator, and system is in forward flow. 

Homogenizer 

The homogenizer may be used as timing pump. It is a positive pressure pump; if not, then it cannot supplement flow. Free circulation from outlet to inlet is required and the speed of the homogenizer must be greater than the rate of flow of the timing pump. 

Magnetic flow meterMagnetic flow meter and centrifugal pump arrangements 

Magnetic flow meters (shown on the right) can be used to measure the flow rate. It is essentially a short piece of tubing (approximately 25 cm long) surrounded by a housing, inside of which are located coils that generate a magnetic field. When milk passes through the magnetic field, it causes a voltage to be induced, and the generated signal is directly proportional to velocity. Application of the magnetic flow meter in the dairy industry has centered around its replacing the positive displacement timing pump as the metering device in HTST pasteurizing systems, where with certain products the timing pump rotors reportedly wear out in a relatively short period of time. In operation, the electrical signal is sent by the magnetic flow meter to the flow controller, which determines what the actual flow is compared to the flow rate set by the operator. Since the magnetic flow meter continuously senses flow rate, it will signal the electronic controller if the actual flow exceeds the set flow rate for any reason. If the flow rate is exceeded for any reason, the flow diversion device is put into diverted flow. A significant difference from the normal HTST system (with timing pump) comes into focus at this point. This system can be operated at a flow rate greater than (residence time less than) the legal limit. However, it will be in diverted flow and never in forward flow.
Another magnetic flow meter based system with an AC variable frequency motor control drive on a centrifugal pump is also possible in lieu of a positive displacement metering pump on a HTST pasteurizer.  This system does not use a control valve but rather the signal from the magnetic flow meter is transmitted to the AC variable frequency control to vary the speed of the centrifugal pump. The pump, then controls the flow rate of product through the system and its holding time in the holding tube.